BLOG

Changes in building use, the renewal of mechanical services, or the addition of new service lines may require existing hanger and support systems to be reassessed. Changes in pipe diameters, the addition of air ducts, the replacement of mechanical equipment, or the rerouting of existing services can directly affect the loads on support systems and their connection points.

Strengthening mechanical services supports in existing buildings should therefore involve more than simply adding new profiles or connection components. Safe implementation requires an assessment of existing conditions, identification of current loads, verification of structural connections, and a solution designed through engineering calculations.

Why Should Mechanical Services Supports Be Reassessed?

Mechanical systems may undergo various modifications throughout a building’s service life. Replacing existing equipment with higher-capacity models, adding new branches to pipelines, or combining different building services on a shared support system can alter the load conditions originally anticipated.

The main circumstances that may require support systems to be reassessed include:

  • Changes to existing pipe, duct, or cable tray routes
  • The addition of new service lines
  • Changes in pipe diameters, insulation thicknesses, or the conveyed fluid
  • The replacement of mechanical equipment or increases in equipment capacity
  • Corrosion, deformation, or loose connections in existing support profiles
  • Changes in the building’s intended use
  • The inclusion of current seismic design criteria in the project scope
  • The identification of inadequate existing suspension points during maintenance or refurbishment work

The presence of any of these conditions does not necessarily mean that the system is inadequate. The need for strengthening can only be determined by assessing the existing supports, connections, and current loads together.

What Should an Existing Condition Assessment Cover?

The assessment of mechanical services support systems begins with documenting existing site conditions. The inspection should cover not only the visible profiles but also all connections to the supported services and the building structure.

Existing Service Loads

When assessing pipelines, the loads from the conveyed fluid, insulation, valves, flanges, and other fittings must be considered alongside the pipe’s own weight. Actual operating loads must also be established for air ducts, cable trays, and mechanical equipment.

Where multiple building services share a support, the way their loads are transferred to the system must also be assessed. Adding a new service line to an existing framework can affect the entire support system, rather than just the new line.

Condition of Profiles and Connection Components

Existing profiles should be checked for section loss, corrosion, bending, and permanent deformation. Loose bolted connections, unsuitable connection components, or unverified modifications made during installation can also affect system performance.

A profile that appears sound does not necessarily have sufficient capacity for current loads. Its cross-section, span, connection arrangement, and applied loads must be considered together.

Structural Connection Points

One of the most important stages of the assessment is examining how the hanger and support system is connected to the building structure. Connection methods differ between reinforced concrete and steel structures. Anchor type, edge distances, the condition of the supporting surface, and the load transfer path into the structure must be checked for each project.

Adding a new profile or seismic brace to an existing connection point does not mean that the connection can carry the additional loads. The building structure, anchors, and support system must be assessed together.

Hanger Spacing and System Geometry

Hanger spacing, cantilever lengths, profile spans, and connection angles directly affect system behaviour. Removing or relocating a suspension point during site modifications can change the load distribution.

The existing system should therefore be assessed as a whole along the service route, rather than solely through individual connections.

How Do Changes in Service Loads Affect Support Systems?

One of the most common situations in refurbishment projects is the addition of a new service line to an existing support system. Where space is limited, using existing profiles to support new pipes, ducts, or cable trays may be considered.

However, additions made without calculating the existing support’s suitability for the new loads can lead to:

  • Increased profile deflection
  • Additional forces at connection points
  • Changes in the loads transferred to anchors
  • Displacement or misalignment of existing service lines
  • An inadequate seismic bracing arrangement

Every system modification should therefore be assessed against the existing support’s load capacity and connection conditions. Where necessary, the existing system can be strengthened, certain sections replaced, or an independent support framework provided for the new services.

How Can Mechanical Services Supports Be Strengthened?

The strengthening method depends on the condition of the existing system, service loads, structural connection points, and physical constraints within the installation area. Since every building and service route is different, there is no single strengthening solution suitable for all projects.

Depending on project conditions, suitable methods may include:

  • Reinforcing existing profiles with appropriately sized sections
  • Replacing inadequate or damaged support members
  • Reducing profile spans by introducing additional support points
  • Reconfiguring cantilever and frame geometry
  • Replacing connection components to suit current load conditions
  • Providing a new modular framework independent of the existing support system
  • Rerouting services to improve load distribution
  • Adding or repositioning seismic braces according to project requirements

The selected solution must suit the existing building, service operating conditions, and maintenance requirements. When increasing capacity at one point, care must be taken to avoid transferring loads to another connection in an uncontrolled manner.

Advantages of Modular Support Systems in Existing Buildings

Installation space is often limited in refurbishment and conversion projects. Existing service lines, structural elements, and other building services can make it difficult to position new supports. Under these conditions, modular support systems simplify installation through their adaptability to different dimensions and geometries.

Their bolted connections allow various support frames to be assembled without on-site welding. Profile lengths, cantilever dimensions, and connection angles can be adjusted to suit project requirements. This allows solutions to be developed for areas where completely dismantling existing services is not feasible.

Heavy-Duty Modular Support Systems may be considered for pipelines requiring high load capacities, long spans, or mechanical equipment supports. Profiles and connection components must be selected according to the applied loads and support geometry.

The installation flexibility offered by modular systems does not replace engineering calculations. Profile sections, connection components, and connections to the building structure must be checked against current project loads.

Seismic Safety and the Importance of Connection Points

The ability of mechanical services supports to safely carry vertical loads does not necessarily mean that the system is adequate under seismic loading. During an earthquake, pipelines, air ducts, cable trays, and mechanical equipment may move in different directions. These movements can impose additional demands on hangers, connection points, and service joints.

The Turkish Building Earthquake Code includes provisions for the seismic design of nonstructural building components. In refurbishment and strengthening work carried out in existing buildings, seismic requirements should be assessed according to the building’s characteristics, the function of the services, and the project criteria.

Depending on project conditions, rigid and cable seismic bracing systems can be used to limit the movement of pipes, ducts, and other building services during an earthquake.

When retrofitting seismic braces to an existing system, the following factors should be considered together:

  • The weight and route of the service line
  • The condition of existing vertical hangers
  • The connection angle of the seismic brace
  • The suitability of the connection to the building structure
  • Thermal expansion and operational movement of the services
  • Potential clashes with other building services
  • The arrangement of seismic braces in different directions

Simply adding a seismic brace does not automatically make the existing vertical supports or structural connections adequate. The vertical support system, seismic braces, and connections to the building structure must be assessed as a whole.

How Should the Strengthening Process Be Planned?

Strengthening mechanical services supports in existing buildings should follow a sequence of technical stages.

Documenting the Existing System

Service routes, suspension points, profile sections, and connection details are identified through site surveys. Where existing design and installation drawings are available, they are compared with actual site conditions.

Determining Current Loads

The weights of existing and proposed services, equipment loads, and operating conditions are established. The effects of planned modifications on supports and connections are assessed.

Performing Engineering Calculations

Profiles, connection components, anchors, and structural connection points are checked against current loads. Static and dynamic effects are assessed together where necessary.

Designing the Appropriate System

The sections of the existing system to be retained, replaced, or strengthened are identified. Modular supports and rigid or cable seismic braces are arranged according to project conditions.

Checking Site Installation

Installation is monitored to verify that the specified profiles, connections, and anchors are fitted in the correct locations. Necessary site changes should only be made after their effects on support system performance have been assessed.

Installation and Engineering Approach

Mechanical services support systems in existing buildings require more site information and coordination than those in new-build projects. The need to keep existing services operational, limited installation space, and incomplete information about previous installations can all affect the strengthening process.

To develop a safe and practical solution:

  • Inspect the existing system on site
  • Determine current service loads
  • Check profile and connection capacities
  • Assess load transfer to the building structure
  • Evaluate project-specific seismic requirements
  • Coordinate installation details with other building services disciplines

Darhan supports the assessment of mechanical services support systems in existing buildings through static and dynamic load analyses, seismic load calculations, support system design, modular support systems, and seismic bracing solutions tailored to project requirements.

Conclusion

Strengthening mechanical services supports in existing buildings involves more than replacing old profiles or adding new supports. The process requires a combined assessment of existing loads, profiles and connections, fixings to the building structure, and seismic requirements.

A properly planned approach can adapt existing services to new operating conditions, address inadequate support points, and improve their safety under seismic loading.

When selected and applied according to engineering calculations and site conditions, modular support systems, heavy-duty supports, and seismic bracing solutions provide a flexible, controlled, and practical framework for refurbishment and conversion projects.